Hertel exophthalmometer

Witryna1 paź 1999 · The most widely used method is the Hertel exophthalmometer (Migliori and Gladstone, 1984;Dunsky, 1992), which measures the distance from the lateral orbital rim to the corneal surface in a ... Witryna3 cze 2009 · The same Hertel exophthalmometer was used throughout the study. The Bland–Altman method was used to analyse the intra‐observer and inter‐observer agreement. Results: The mean intra‐observer and inter‐observer agreements on the interorbital distance (IOD) were ±3.31 mm and ±6.39 mm, respectively. The …

Normal Values of Hertel Exophthalmometry in a Chinese Han

Witryna24 wrz 2012 · Aim 1. In order to determine intrauser reliability of the Hertel exophthalmometer, patients will have 2 independent exams using the Hertel exophthalmometer on the same day performed by each of the same researcher (either DAC or HLP) in a blinded fashion. For each patient, we will independently measure … Witryna1 lip 2009 · DOI: 10.1111/j.1475-1313.2008.00617.x Corpus ID: 23472070; Intra‐observer and inter‐observer variation of Hertel exophthalmometry @article{Lam2009IntraobserverAI, title={Intra‐observer and inter‐observer variation of Hertel exophthalmometry}, author={Andrew K. C. Lam and Chun-fai Lam and Wai-kit … chamber fergus falls https://ryanstrittmather.com

Proptosis in Dysthyroid Ophthalmopathy: ACase Series of 10,931 …

Witryna19 lut 2024 · The Hertel exophthalmometer offers accurate and reproducible measurements and the advantage of comparing one eye with the other during the same examination. In Hertel exophthalmometry, the distance between the two lateral orbital rims is engraved on the horizontal bar, which carries the sliding mirrors. This baseline … Witryna17 lip 2015 · Although Hertel exophthalmometer and CT measurements are similar and strongly correlated, they do not agree well with each other in the presence of proptosis. ABSTRACT Aim: To determine the correlation and agreement between Hertel exophthalmometry and computed tomography (CT) of the orbits in measuring … WitrynaE ditor,—The common method used in Hertel exophthalmometry involves aligning the corneal apex with the reference cone on the exophthalmometer and noting the position of this alignment on the millimetre scale (method 1).Keeler, the manufacturers of the exophthalmometer, recommend that the reference cone is aligned with the reference … chamberet commerces

Cross-sectional computed tomography assessment of …

Category:Hertel exophthalmometer versus computed tomography scan in …

Tags:Hertel exophthalmometer

Hertel exophthalmometer

Hertel Exophthalmometer - Ophthalmic Data

WitrynaHertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy Javascript is currently disabled in your browser. Several features of this site will not function whilst javascript is disabled. Witryna19 gru 2016 · The Hertel exophthalmometer is used to determine the axial position of the eyes. The instrument is placed on the lateral orbital rim of each side, using as small of a base as possible. Depending on the device, lines on the prism are placed into position by moving the examiners view point to determine the measurement.

Hertel exophthalmometer

Did you know?

Witryna19 gru 2016 · The Hertel exophthalmometer is used to determine the axial position of the eyes. The instrument is placed on the lateral orbital rim of each side, using as … Witryna1 gru 2003 · Hertel exophthalmometer is the most commonly used device, including in Sanglah General Hospital as tertiary care centrein Bali. The exophthalmometric measures tend to vary with age, sex, …

WitrynaExophthalmometry, the quantitative assessment of the position of the globe in the orbit, is a clinically useful measurement. The purpose of this study was to examine the … WitrynaNaugle exophthalmometer In case of acquired or congential asymmetry of the lateral orbital rims a Hertel exophthalmometer is misleading (see above). In these cases, a Naugle exophthalmometer is preferred since the referring structure is not the lateral orbital rim but the frontal and infraorbital structures.

WitrynaExophthalmometry is frequently used as a tool in the evaluation of proptosis. The purpose of this study was to compare the clinical usefulness of the newly developed … Witryna3 wrz 2024 · Table 3 Comparison of the Hertel exophthalmometer, computed tomography (CT), and 3D reconstruction software in patients who underwent orbital …

WitrynaThe exophthalmometer is an instrument designed to measure the forward protrusion of the eye. This instrument provides a method of evaluating and recording the …

WitrynaHertel exophthalmometry was done for all cases by a single ophthalmologist using Hertel exophthalmometer (Oculus Inc., Wetzlar, Germany). Cycloplegia was obtained by alternatively instilling one drop of cyclopentolate 0.5% and one drop of tropicamide 0.5% at intervals of 5 minutes for a total of three drops per cycloplegic agent. chamber etowah gadsdenWitrynaPurpose. This observational case series investigated the occurrence and distribution of proptosis in Japanese patients with dysthyroid ophthalmopathy (DO). The relationship among lid retraction, lid chamber exeterWitryna6 lut 2024 · Ein übliches Exophthalmometer (nach Hertel) besteht aus einer bestimmten Anordnung mit Messvorrichtung und Spiegeln, so dass die Augen von der Seite betrachtet und ausgemessen werden können. Gemessen wird, wie weit der Abstand der Hornhaut nach vorne von der seitlichen Kante der Augenhöhle ist. chamberfest prior lakeWitryna1 sty 2024 · The same Hertel exophthalmometer was used throughout the study. The Bland-Altman method was used to analyse the intra-observer and inter-observer agreement. The mean intra-observer and inter ... chamberfestcleveland.comWitrynaInternational standardization of Hertel exophthalmometry is required in order to compare exophthalmometry data in the literature reliably. Reliability of exophthalmos … happy new year in creeWitrynaThe exophthalmometer is an instrument designed to measure the forward protrusion of the eye. This instrument provides a method of evaluating the recording the progression and regression of the prominence of an eye caused by disorders such as thyroid disease and tumors of the orbit. This instrument consists of a horizontal calibrated bar with ... happy new year in croatian languageWitrynaObjective: To compare the reliability of orbital parameters calculated using 2-dimensional computed tomography (CT) and Hertel exophthalmometry when measuring … chamberfest 2020